IV arm wrap around with embedded circular bloodline for IV training.This IV training arm sleeve is great for training to take blood, insert IVs, give injections, or for vaccination purposes
Realistic arm wrap with protective thermo-plastic and muscle
layer silicone blood vessels.
This model has 2 veins for IV cannulation training.
The skin is made with super-soft durable silicone.
The veins are partly visible and can be palpated.
This device can be used in conjunction with an IV tourniquet.
Contents:
Skin layer
Muscle layer
Thermo-plastic protective layer
Tubing & replacement tubing
Velcro attachment
Syringe 30ml
Syringe 10 ml
How to use the IV cannulation arm wrap:
Prepare thermo-plastic layer
Use hot water to soften the thermo-pastic
Dry off the layer andensure it is cool enough to apply to the subjects skin but still malleable
Place muscle layer on top of the protective thermo-plastic layer
Lay vessels into the grooves in the muscle layer
Apply Velcro underlayer
Apply skin layer
Set up for cannulation
Use red tinted water and fill the 30ml syringe
Connect the syringes to both leur locks - 30ml at the distal end, 10 ml at the proximal
Prime the vessel tube with the blood until the 10ml syringe is full
Remove the 30ml syringe and hide the filling end as required
Add light pressure to the 10ml syringe. This will provide the flashback for the user. - once flashback is achieved, you no longer need to provide pressure, unless simulating phlebotomy
Use 22 gauge cannulas or smaller, ensuring longevity of the arm
After use the tubes can be turned or moved through the model or replaced as needed
To replace the tube, disconnect the luer lock connectors, remove the damaged tubing and replace with the supplied spares
Lightly lubricate the outside of your replacement tubing with petroleum jelly and insert.
Reattach your luer lock connectors
For further information or instructions, see our video on youtube: MEDICFX NZ
This IV training arm wrap can also be used to take blood.
This model can achieve flashback when cannulating so long as pressure is maintained on the proximal syringe.
Pressure may cause leaks in previous puncture sites inside the model.
After some use areas of the model may become perforated.
These surface perforations at needle sites can be repaired with silicone from our repair kits. [link]
To repair the model :
Use a platinum silicone repair kit
Mix equal amounts of A and B silicone. Clean the area with some alcohol.
Stretch the perforated area and fill holes with the silicone.
Stop stretching the area and wipe off any residue with a tissue.
Cures within 1 hour.
Care instructions:
The model can be washed with warm water, dry thoroughly.
You can use talc powder to dull shiny areas on the model.
Ensure this product is clean and dry before storing
Flush lines with Iso-alcohol to prevent mould
Store in a cool, dry environment out of direct sunlight.
Warranty:
MEDICFX warrants that the products supplied will be of good quality
and reasonably fit for the purpose(s) mentioned in the descriptions.
All products that are faulty or damaged need to be notified, with a
photo of the damage, within a week after receiving the products.
If the damage or fault is due to fabrication, the faulty product can be returned and repaired,
replaced, or refunded.
MEDICFX offers a 6-month warranty on silicone parts of your model.
With normal, gentle use no rips or tears should occur.
All our products are handmade and may have small imperfections
and slight variations from our webshop image.